Vibrating Wire Strain Gauges Model IG 1200/1300


Strain Gauge Image 1 Strain Gauge Image 2


Externally mounted magnet assembly on the other hand is prone to corrosion as it is made in two halves, which are externally clamped on to the tube. This does not ensure proper sealing at the joint. Thus water can seep and with time cause corrosion on the magnet, resulting in failure.

Embedment type strain gauges are provided with built-in stainless steel flanges while the groutable and arc weldable type have the same design but different end plugs. By the use of the appropriate type of mounting blocks, the same strain gauge can be arc welded on to the steel structures such as tunnel linings and supports or grouted or epoxy bonded on the surface of concrete structures.

To take care of space limitation, for vertical measurement of strain across thin concrete lining, embedment strain gauges with 55mm gauge length are used. For example, on pavements.

Vibrating Wire strain Gauges Model
Model IG 1200
Embedment IG 1200E
Weldable IG 1200W
Groutable IG 1200G
Gauge length 125 mm
Gauge factor 2.487x 10-3 microstrain/Hz2
Range ± 1500 micro strain
Sensitivity 1 microstrain
Material (outer body) Stainless steel
Coil Resistance 140 – 160 Ohm @ 25°C
Thermistor YSI 44005 or equivalent (3k Ohm @ 25°C)

Accessories:


a. 5 position rosette for mounting strain gauge at different angles and in different planes.
b. No-stress container to evaluate strain produced due to factors other than load.
c. Brackets for arc welding on structures or grouting.
d. 6 position junction box to terminate strain gauges installed on Rosette.